en

fa

FA
EN

Dry gas seal control systems for CMQ pumps

Purposes:

√ Ideal for tandem or dual dry gas seals for pumps
√ Provide a certain pressure and flow of clean dry gas for the seal
√ Monitor the operation of seals with alarm

Features:

√ Designing, manufacturing and inspection refer to GB/T150
√ Piping components and instrument configurations in accordance with AP1682
√ Panel or box structures are available:
1.Operation and easy maintenance for panel structures
2.Simple and beautiful appearance for box structures

Special design:

√ Customized designing and manufacturing available

Piping plans:

√ Ideal for auxiliary systems for mechanical seals API 682 Plan 72,74,75,76

Configurations and functions:

S/N

Configurations

Functions

Filter

Filter particles in the gas meet requirements of booster pump

Self-operated pressure regulator

Stabilize the pressure source to the set value, generally integrated with the filter

Check valve

Prevent process media from back-streaming into the nitrogen pipe network, and prevent flare gas from back-streaming into the dry gas seal system

Leakage collection tank

Collect the process media of seal leakage

Flowmeter

Monitor flow of systems, and generally integrated with the flow transmitter

Liquid level meter

Monitor the liquid level of leakage collection tanks

Pressure switch / pressure transmitter

Monitor pressure of systems and report to PCS rooms

Flow switch / Flow transmitter

Monitor flow of systems and report to PCS rooms

Level switch / level transmitter(optional)

Monitor the liquid level of leakage collection tanks and report to central control room

Pressure gauge (optional)

Monitor pressure of systems

Interface details:

   Interface details

Interface identification

Purposes or descriptions

  Connection dimensions

 

CMQ41*

CMQ251*

CMQ261*

 

A

Pipeline nitrogen

DN15

DN15

DN15

B

Seal gas

Φ10

Φ10

Φ10

C

Vent

/

Φ10

/

D

To flare

/

DN15

DN15

E

Inlets of collection tanks

/

DN15

/

G

Drain of collection tanks

/

DN20

/

   Interface details

Interface identification

Purposes or descriptions

  Connection dimensions

 

CMQ41*

CMQ251*

CMQ261*

 

A

Pipeline nitrogen

DN15

DN15

DN15

B

Seal gas

Φ10

Φ10

Φ10

C

Vent

/

Φ10

/

D

To flare

/

DN15

DN15

E

Inlets of collection tanks

/

DN15

/

G

Drain of collection tanks

/

DN20

/

1 *, CMQ4 is used for auxiliary systemfor mechanical seals API 682 Plan74, 2 * ,CMQ25 is used for auxiliary systemfor mechanical seals API 682 Plan72 + 75 3 *, CMQ26 is used for the auxiliary system for mechanical seals API 682 Plan72 + 76