CMG3 reservoir systems

Purposes:

√ Supply buffer fluid/barrier fluid for mechanical seals to optimize the working environment of dual mechanical seals
√ Monitor the operation of seals with alarm

Features:

√ Designing, manufacturing and inspection refer to GB/T150
√ Piping components and instrument configurations in accordance with AP1682
√ Level sight glass and cooling coil are available
√ Modular design of components

Special design:

√ Optional disassembly structure, easy for internal cleaning
√ Customized designing and manufacturing available

Piping plans:

√ Ideal for auxiliary systems for mechanical seals API 682 Plan52、53A

Configurations and functions:

S/N

Configurations

Functions

reservoir

Store buffer / barrier fluid and collect leaking media

Level sight glass

Monitor the liquid level

cooling coil

Cool the buffer/barrier fluid

Pressure switch / pressure transmitter

Monitor the pressure and report to central control room

Level switch / level transmitter

Monitor the pressure and report to central control room

Pressure gauge (optional)

Monitor the pressure

Thermometer (optional)

Measure the temperature of barrier fluid

Manual rehydration pump (optional)

A small amount of rehydration for running systems without

Interface details

   Interface details

Interface identification

Purposes or descriptions

  Connection dimensions

CMG3-12521*

CMG3-20521*

CMG3-1253A2*

CMG3-2053A2*

BI

Bufer/barrier fluid inlets

DN15

DN20

DN15

DN20

BO

Buffer/barrier fluid outlets

DN15

DN20

DN15

DN20

CI

Cooling water inlets

DN15

DN15

DN15

DN15

CO

Cooling water outlets

DN15

DN15

DN15

DN15

V

Torch interfaces

DN15

DN15

/

/

P

Pressurized interface

/

/

DN15

DN15

S

Rehydration interface

funnels

funnels

funnels

funnels

S1

Reserved interfaces of rehydration pumps

/

/

M16×1.5M

M16×1.5M

D

Drain

DN15

DN15

DN15

DN15

   Interface details

Interface identification

Purposes or descriptions

  Connection dimensions

CMG3-12521*

CMG3-20521*

CMG3-1253A2*

CMG3-2053A2*

BI

Bufer/barrier fluid inlets

DN15

DN20

DN15

DN20

BO

Buffer/barrier fluid outlets

DN15

DN20

DN15

DN20

CI

Cooling water inlets

DN15

DN15

DN15

DN15

CO

Cooling water outlets

DN15

DN15

DN15

DN15

V

Torch interfaces

DN15

DN15

/

/

P

Pressurized interface

/

/

DN15

DN15

S

Rehydration interface

funnels

funnels

funnels

funnels

S1

Reserved interfaces of rehydration pumps

/

/

M16×1.5M

M16×1.5M

D

Drain

DN15

DN15

DN15

DN15

Notes: *1 ، CMG3-1252, CMG3-2052 refer to the reservoirs of of plan52 respectively, with standard volume of 12L and 20L.

2*, CMG3-1253A, CMG3-2053A refer to the reservoirs of plan53A respectively, with standard volume of 12L and 20L.

cmg3