en

fa

FA
EN

CMG3-53B systems

Purposes:

√ Designing, manufacturing and inspection refer to GB/T150
√ Piping components and instrument configurations in accordance with AP1682
√ Contain accumulators, heat exchangers, pipe components and instruments
√ Water-cooled or air-cooled heat exchangers are available according to the site conditions

Features:

√ Improve the working environment of dual mechanical seals by supplying barrier fluid and dissipate friction heat of seal faces in time
√ Monitor the operation of seals with alarm

Special design:

√ Customized designing and manufacturing available

Piping plans:

√ Ideal for auxiliary systems for mechanical seals API 682 Plan 53B

Configurations and functions:

S/N

Configurations

Functions

Accumulator

Pressure source for systems and storage of barrier fluid to ensure operation cycle of systems

Heat exchanger

Cool the barrier fluid

Pressure switch / pressure transmitter

Monitor the pressure of barrier fluid and transmit to PCS room

Temperature transmitter

Measure the gas temperature in the accumulator

Pressure gauge (optional)

Measure the bladder pressure in the accumulator

Thermometer (optional)

Measure the temperature of barrier fluid

Manual rehydration pump (optional)

Refilling without pump shuntdown

Interface details

   Interface details

Interface identification

Purposes or descriptions

  Connection dimensions

Shaft≤60mm1*

Shaft>60mm1*

BI

Barrier fluid inlets

DN15

DN20

BO

Barrier fluid outlets

DN15

DN20

CI

Cooling water inlets

DN15

DN20

CO

Cooling water outlets

DN15

DN20

D

Drain

DN15

DN15

V

Vent

DN15

DN15

S

Reserved interface rehydration pumps

M16×1.5M

M16×1.5M

N

Accumulator charging interface

M14×1.5M

M14×1.5M

   Interface details

Interface identification

Purposes or descriptions

  Connection dimensions

Shaft≤60mm1*

Shaft>60mm1*

BI

Barrier fluid inlets

DN15

DN20

BO

Barrier fluid outlets

DN15

DN20

CI

Cooling water inlets

DN15

DN20

CO

Cooling water outlets

DN15

DN20

D

Drain

DN15

DN15

V

Vent

DN15

DN15

S

Reserved interface rehydration pumps

M16×1.5M

M16×1.5M

N

Accumulator charging interface

M14×1.5M

M14×1.5M

Note:1*,When shaft≤60mm, accumulator volume is 25L; when shaft 60mm, accumulator volume is 40L.